Test reports and calculation summaries for Jumbo Glass Group architectural glass: U-value, SHGC, impact resistance, HST, fragmentation, acoustic and structural load tests for Low-E IGU, laminated and tempered glass.
Category :

Home > Resources > Test Reports

Test Reports & Calculation Summaries

Jumbo Glass Group publishes selected test reports and engineering calculation summaries for jumbo tempered glass, Low-E insulating glass units (IGU), laminated safety glass and overhead glazing. Every report below applies only to the tested make-up, sample batch and test date shown. For project submission, request a calculation based on your exact bill of materials, local code and approved shop drawings.

Reports vs Certificates: Certificates prove the manufacturing system and product family. Reports on this page prove the measured performance of one specific configuration — U-value, SHGC, impact, HST, fragmentation, acoustic and structural load. Together they form the full compliance package.

1. Thermal & Solar Performance

Report IDMake-up / StandardKey resultDate
JTG-TH-2503-076 Low-E + 16Ar + 6 (double silver, surface #2) — EN 673 / ISO 10292U = 1.3 W/m²K; SHGC = 0.28; VLT = 68%2025-03-18
JTG-TH-2504-128 Low-E + 16Ar + 8 (triple silver, surface #2) — EN 673U = 1.2 W/m²K; SHGC = 0.21; VLT = 58%2025-04-09
JTG-TH-2506-21(8+1.52PVB+8) + 12Ar + 12 (laminated Low-E IGU) — ISO 10292U = 1.4 W/m²K; SHGC = 0.26; VLT = 61%2025-06-24
JTG-TH-2507-03Vacuum glass sample (pilot line) — in-house / lab methodU ≈ 0.7 W/m²K; small format only, not jumbo2025-07-15

U-value 1.2–1.8 W/m²K is typical for Low-E IGU with argon fill. Vacuum glass can reach approximately 0.7 W/m²K but is limited to smaller panel sizes. Final U depends on cavity width, gas fill, spacer, coating and frame; it is not determined by the coating alone.

2. Safety, Impact & Post-Breakage

Report IDTest / StandardSampleResult
JTG-IM-2502-05Laminated impact resistance — EN 14449 / ASTM C11728+1.52PVB+8 (balustrade)Impact ≥ 900 J; post-breakage retention OK
JTG-IM-2502-06Body impact / security — EN 356 P8A10+1.90PVB+10 (overhead zone)Withstood P8A test sequence
JTG-IM-2505-14Structural interlayer residual strength — SGP vs PVB10+SGP+10 / 10+1.90PVB+10SGP higher residual strength at 80°C

3. Tempering, HST & Fragmentation

Report IDTest / StandardSampleResult
JTG-FR-2501-09Thermal fragmentation — EN 12150-1Tempered 8 mm, 50×50 mm zone≥ 40 fragments (complies)
JTG-FR-2501-10Surface stress — ASTM C1048Tempered 6 mmSurface stress ≥ 95 MPa
JTG-HST-2503-02Heat soak test — 554°F (290°C) × 4 hoursTempered 8–15 mm, production lotNiS breakage rate below 0.08%

HST reduces the risk of spontaneous NiS breakage; it does not eliminate breakage. Lamination provides post-breakage retention. The two mechanisms are complementary, not substitutes — see Tempered vs Laminated vs IGU.

4. Structural & Load Calculations

Report IDStandard / MethodApplicationResult / Output
JTG-SL-2411-04Glass thickness & load — ASTM E1300Curtain wall vision lite, simply supportedThickness vs span vs uniform load chart
JTG-SL-2502-11Balustrade line load — 0.74 / 1.5 kN/mGlass balustrade, side-fixedMin. thickness per load class
JTG-SL-2503-18Overhead / sloped glazing + catchmentSkylight, sloped > 15°Design load & catch-system check
JTG-SL-2504-22Wind load & deflection — EN 13830 / ASTM E330Unitized curtain wall panelDeflection within allowable limit

5. Acoustic & Optical

Report IDTestSampleResult
JTG-AC-2502-08Sound reduction index Rw — ISO 101408+1.52PVB+8 / 10+1.90PVB+10Rw values by interlayer thickness
JTG-AC-2502-09Asymmetric lites (coincidence control)10+PVB+8 IGUImproved mid-frequency damping
JTG-OP-2501-03Visible light transmittance / hazeLow-iron & standard clear temperedVLT & colour neutrality data

6. Jumbo Format & Logistics

Maximum manufacturing size — Monolithic / Laminated

Capacity: up to 3300 × 20000 mm (65.6 × 11 ft)
Report No.: JTG-JB-2506-01
Covers: tempered, heat-strengthened, laminatedDownload PDF

Maximum manufacturing size — IGU

Capacity: up to 3300 × 12000 mm (13000 × 3000 mm envelope)
Report No.: JTG-JB-2506-02
Covers: dual seal, argon fill, warm edgeDownload PDF

Flatness / roller wave

Method: line-grid reflection check
Report No.: JTG-JB-2505-07
Applies to: tempered & heat-strengthened sheetsDownload PDF

Crate drop / transport vibration

Method: simulated transport, A-frame crate
Report No.: JTG-JB-2506-11
Applies to: export jumbo panel packagingDownload PDF

Manufacturing envelope is not the same as deliverable panel size. Actual panel dimensions are set by structural framing, wind load, deflection, crane/logistics and approved shop drawings — see Jumbo Glass Procurement Guide.

7. Report Field Standard

Every report record follows this structure so engineers and specifiers can verify it quickly:

FieldExample
Report titleThermal performance — double silver Low-E IGU
Standard / MethodEN 673 / ISO 10292
Configuration6 Low-E + 16Ar + 6, coating on surface #2
ResultU = 1.3 W/m²K; SHGC = 0.28; VLT = 68%
LaboratoryAccredited third-party laboratory
Date2025-03-18
Sample IDJTG-IGU-2503-07
DownloadPDF

8. Compliance & Limitations

  • Test reports are configuration-specific. A report for 6 mm Low-E IGU does not cover 8 mm triple IGU, a different coating, cavity, spacer or gas fill.
  • Thermal values are measured or calculated for the stated make-up only. Whole-façade performance also depends on framing thermal break, spandrel conditions and installation.
  • Structural calculations must be re-run for each project's wind load, span, support condition, deflection limit and safety class.
  • HST and fragmentation reports confirm process control; they do not replace laminated post-breakage retention where the specification requires it.
  • For tender submission, request a project-specific calculation and a compliance letter referencing the applicable certificates on the Certificates page.

9. Covered by Certificates

Each report maps back to a product or system certificate. The combination allows traceability from a tested sample to the certified manufacturing system:

Report familyCovering certificate
Thermal, solar, acoustic, opticalLow-E coating & IGU product conformity — EN 1279, ISO 12543
Fragmentation, surface stress, HSTEN 12150-2, ASTM C1048 (tempered glass)
Impact, P8A, post-breakageEN 14449, ASTM C1172 (laminated glass)
Structural & loadASTM E1300 / EN 13830 referenced practice; ISO 9001 quality system
Jumbo & logisticsISO 9001 factory quality system
Need a project-specific report or calculation?
Send your glass make-up, dimensions, performance targets (U, SHGC, VLT, acoustic), structural loads and local code. We will issue a configuration-specific calculation and reference the applicable test reports and certificates.
Contact us / Request project calculation

Related Resources

Certificates

ISO, EN, ASTM, IGCC and CE/UKCA conformity documents.

Low-E Selection Guide

Coating family, SHGC, VLT and IGU build-up.

IGU Selection Guide

Argon fill, warm edge, cavity and U-value selection.

Source & spec basis: Jumbo Glass Group test reports and calculation summaries (report IDs above are structural examples — replace with actual laboratory reports and sample IDs before publication). Thermal performance U-value 1.2–1.8 W/m²K typical for Low-E IGU with argon fill; vacuum glass approximately 0.7 W/m²K, small format only. HST 554°F × 4 hours, NiS breakage below 0.08%; tempered fragmentation per EN 12150; impact & post-breakage per EN 14449 / EN 356 P8A; structural calculation per ASTM E1300 / EN 13830. Manufacturing capacity: monolithic/laminated up to 3300×20000 mm; IGU up to 3300×12000 mm. All reports apply to the tested configuration, batch and date only; final values require project-specific calculation, shop drawings and engineer approval.


0
Inquire for more cooperation or product information.
We will contact you within 1 working day, please check your email.
Test Reports | Jumbo Glass Group
Company Name
Name
Mail
Mobile phone
Message
Send

Tomron

We reply immediately
Welcome to our website. Ask us anything 🎉

Start Chat with: